Elation 15R Specifications Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
Platinum Beam 15R™
©Elation Professional® Los Angeles Ca. 90040 www.ElationLighting.com
33
10. DMX ADDRESSING
Setting the DMX address -After the fixture is turned “ON” it will immediately complete a
reset process that test all the fixture’s functions. When the reset process concludes the
LCD will display the fixture’s current DMX. If the fixture is not receiving a DMX signal, the
display will flash continuously. To set or adjust a DMX address, please follow the
procedure below:
1. Toggle through the menu by pressing the Up and Down buttons until the
display reads “Set DMX Address.” Tap the enter button to make changes to
the address.
2. While the current three-digit address is flashing use the “UP” and “DOWN”
buttons to select a new address. Once the new address has been selected,
lock the new address into the fixture’s memory by pressing the “ENTER”
button.
The DMX address is non-volatile and will remain in the fixture’s memory even when
the power to the unit is switched off. Memory is backed-up and retain by an internal
power source that should last about five years
Remote DMX addressing (RDMX) / Address Via DMX- This function allows the DMX
address to be changed remotely from a DMX console. This setting requires special
settings for both the controller and the fixture. RDMX is on by default. Follow the
procedure listed below to access the RDMX functions:
Fixture Settings:
1. Access the main menu and use the UP or DOWN to get to the
“Personality” menu, then press ENTER
2. Once in the “Personalities” menu, tap the UP or Down to get to the
“Status Settings “ menu, press ENTER.
3. Once in the “Status Settings” tap the UP or Down to get to the “Address
via DMX” function and press ENTER.
4. “Address via DMX” is the function that turn the RDMX function on and
off.
5. Press the UP button to display “ON” to activate this function, or “OFF”
to deactivate this function.
6. Press ENTER to confirm.
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 57 58

Comments to this Manuals

No comments