Elation Professional - www.elationlighting.com - Page 11
the external Record LED will also light up. And when the internal Play LED is “on”, the
external Play LED will light up, too.
Note: In the previous table, “1” means the switch is ”on”, while “0” means “off”.
8 Note information for usage
The CF card must be either in, or taken out of the unit before turning on the machine,
otherwise, this will result in malfunction. This unit can only use 32M CF card, and if the
card is new, it should be formatted before using.
Choose your desired settings under SETUP mode, and press “Enter” to confirm and
save your settings. Generally speaking, the correspondent sequences under different
modes can only be stored through mode switching.
The STARTUP and SHUTDOWN function is only be available during internal operation.
During CF card operation, the STARTUP and SHUTDOWN functions will be disabled.
If something goes wrong or malfunctions during operation, you can restart the unit by
pressing and holding down the SHUTDOWN and RECORD buttons. Due to the above
operation. Due to this restart operation all recorded data in the unit will be cleared.
9 Troubleshooting (FAQ)
Problem 1: The Program mode is skipped during mode switching.
Cause : In order to protect the data and prevent them from being erased, the Program
mode has been locked.
Recovery : press the MODE button to enter the SETUP mode, select submenu 7 choose
“N” for unlocking.
Problem 2: Nothing happens when the PLAY button is pushed.