Elation COLOR SPOT 150 User Manual

Browse online or download User Manual for Telescopes Elation COLOR SPOT 150. Elation COLOR SPOT 150 User manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - COLOR SPOT 150

USER MANUALVersion 1.0Keep this manual for future needs !© CopyrightReproduction prohibited !COLOR SPOT 150

Page 2

10Fixation via the Omega holders1. Screw each clamp (1) to the included Omega holders (4) with M12 bolt and nut through the hole in the holder.2. Ins

Page 3 - 1. Safety instructions

114.6 DMX- 512 connection, master/slave connectionThe wires must not come into contact with each other, otherwisethe fixtures will not work at all, or

Page 4 - 2.Operating determinations

125. DMX Protocol-16 bit Mode 1 Mode 2 Value Function Type of control Channel Channel1 1 Pan0-255 Pan movement by 530° proportional2 3 Tilt0-25

Page 5 - 3.Description of the device

13 Channel Channel8 8 Rotating gobo rotation 0-127 Gobo rotation proportional 128-189 Forwards gobo rotation from fast to slow proportiona

Page 6 - 4.2Lamp adjustment

14Mode 3 Mode 4 Value Function Type of controlChannel Channel1 1 Pan0-255 Pan movement by 530° proportional2 2 Tilt0-255 Tilt movement by 28

Page 7

15 Channel Channel7 6 Shutter,Strobe,Reset0- Shutter closed step 1-63 Light intensity from 0 to 100% proportional 64-95 Shutter open st

Page 8 - 4.4 Rigging

16The COLOR SPOT 150 can be operated with a controller in controller mode or without the controller in stand-alone mode.Both modes are described in t

Page 9 - DANGER TO LIFE!

178. Stand - alone modeThe fixtures on a data link are not connected to the controller but can execute pre-set programs which can bedifferent for ever

Page 10 - 4.5 Connection to the mains

189. Functions of the control panelThe control panel situated on the front side of the base offers several features. You can simply set the DMXaddres

Page 11 - DMX - output DMX-input

19Note:Disconect the fixtures from the DMX controller before master/slave operating ,otherwise data collisions canoccur and the fixtures will not wor

Page 12 - 5. DMX Protocol-16 bit

2Table of contents1. Safety instructions... 32.O

Page 13 - Channel Channel

20- The number of the hours that the COLOR SPOT 150 has been powered On since thecounter was last reset.Press [ ] or [ ] to return to the menu.I

Page 14 - 6. DMX Protocol-8 bit

21 - Pan reverseThis function allows you to invert the pan movement. Use the [ ] or [ ] buttons to select "On" if you wish thisfeature

Page 15

22 - Display -intensityWith this function you can adjust the display intensity from 20% to 100% . Use the [ ] or [ ]buttons to select the level of

Page 16 - 7.1 DMX addressing

239.5 Test sequencesThis function allows you to run a special demo-test sequences without an external controller, which will show yousome possibilitie

Page 17 - 8. Stand - alone mode

249.6 Stand-alone settingThis menu offers options for stand-alone mode as a selection of the playing program,programming and modifyingcurrent programs

Page 18 - 9.1 Addressing

25- Editing programThis menu item allows you to select a program to edit or create.The COLOR SPOT 150 has one built-in program("tESt") and

Page 19 - 9.3 Fixture informations

26 - Manual control of effectsThe function allows you to control manually the channel functions of the fixture. Use the [ ] or [ ] buttons toselec

Page 20 - 9.4 Personality options

271. Calibration via the control panelPress [ ] and the [ ] or [ ] buttons in order to display the following messages: "Colo, rGob," f

Page 21 - - Display adjusting

28main PCB).The yoke is not located in the default position after the reset.ti.Er.(TILT-head movement error) This message will appear after the reset

Page 22

29Shutter/Dimmer:- Simple dimmer from 0 - 100 %Motors:- 5 high quality stepping-motors controlled by microprocessorsFans:- Two axial fans - one in th

Page 23 - 9.5 Test sequences

3CAUTION!Keep this device away from rain and moisture!Unplug mains lead before opening the housing!FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL C

Page 24 - 9.6 Stand-alone setting

3012. Maintenance and cleaningThe operator has to make sure that safety-relating and machine-technical installations are inspected by an expertafter e

Page 25 - 9.8 Special functions

31operations are only to be carried out by authorized dealers.Please refer to the instructions under "Fitting/Exchanging the lamp".Replacing

Page 26 - -- Fixture code

42.Operating determinationsThis device is a moving-head spot for creating decorative effects and was designed for indoor use only.This device is desi

Page 27 - DMX Calibration protocol:

53.Description of the deviceRear panel of the base12 - Display13 - Mode-button14 - Enter-button15 - Up-button16 - Down-button 6 - DMX output 9 - Fus

Page 28 - 11.Technical specifications

64.Installation4.1Fitting/Exchanging the lampDANGER ! Install the lamp with the device switched off only.Unplug from mains before !To insert the lam

Page 29

7To reduce a hot-spot, pull the lamp in by turning all three screws „A, B, C” clockwise 1/4-turn at a time until thelight is evenly distributed.If the

Page 30 - 12. Maintenance and cleaning

84.4 RiggingDANGER TO LIFE!Please consider the respective national norms during the installation!Theinstallation must only be carried out by an author

Page 31 - 13. Appendix

9The moving-head can be placed directly on the stage floor or rigged in any orientation on a truss without alteringits operation characteristics .Ther

Comments to this Manuals

No comments